SECO-LARM ENFORCER SA-025EQ Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
18
Curtain Sensors
E-9611-2B25
Black Enclosure
2 Beams, 11
1
/
4
” (29cm) long
E-9622-4B25
Black Enclosure
E-9622-4W25
White Enclosure
4 Beams, 22
1
/
2
” (57cm) long
Power Supply Chargers
ST-1206-1.5AQ
ST-240 6-2AQ
ST-2406-3AQ
ST-2406-5AQ
ST-2406-2AQ
Programmable Timers
SA-025Q
Triggered by positive voltage
(+DC), closure of dry contact,
or opening of dry contact.
Adjustable from 1sec to 60min.
Form C relay.
E-9644-6B25
Black Enclosure
E-9644-6W25
White Enclosure
6 Beams, 44
1
/
2
” (113cm) long
E-9660-8B25
Black Enclosure
8 Beams, 60” (152cm) long
E-9680-10B25
Black Enclosure
10 Beams, 80” (203cm) long
Range: Up to 25ft (7.5m) outdoor,
50ft (15m) indoor.
1-Amp relay.
NO or NC Relay output.
S T - 24 0 6 -7 A Q
ST-2406-10AQ
Convert low-voltage AC input power to
low-voltage DC output power.
Regulated and filtered output
voltage.
Short-circuit protection.
Built-in backup battery charger.
Switches to backup battery
automatically in case of power loss.
Multiple program settings.
SA-026Q
M i n i a t u r e :
1
3
/
16
"x2
9
/
32
"x
5
/
8
"
(30x58x16
mm).
Adjustable from 1~180 sec.
Buzzer output.
ST-2406-10AQ Form C relay.
(More timers on pg. 12)
Slimline design: 1
5
/
16
”x
7
/
8
(34x23 mm).
Programmable trigger:
One beam or two adjacent beams.
Long-Range Barrier Sensors
E-9626-2B190Q
2 Pairs, 26” (66cm)
E-9643-4B190Q
4 Pairs, 43” (109cm)
E-9661-6B190Q
6 Pairs, 61” (155cm)
4
E-9679-8B190Q
Frequencies
8 Pairs, 79” (201cm)
Range: Up to 196ft (60m) outdoor,
393ft (120m) indoor.
1-Amp relay output.
NO or NC Alarm output.
Adjustable interruption time.
Built-in heater.
Single Photobeam Detector
E-961-S90WQ
Range: Up to 90ft (30m).
IP66 for Indoor/outdoor use.
Mounts flat or at 90
o
to the wall with no need
for extra brackets.
Adjustable lens angle.
Flush-Mount Beam Sensors
E-932-D33TBQ
Photoelectric
Through-Beam Sensor
Range: 33ft (10m)
E-932-S16RRQ
Photoelectric
Reflective-Beam Sensor
Range: 16ft (5m)
Flush-mount design.
Fits single-gang box.
For entrances, hallways, offices, etc.
Model #
Voltage
Current Current
(DC) (peak)
ST-1206-1.5AQ
6/12 1.5A 2A
ST-2406-2AQ
6/12/24 1.5A 2A
ST-2406-3AQ
6/12/24 2.5A 3A
ST-2406-5AQ
6/12/24 4A 5A
ST-2406-7AQ
6/12/24 7A 7.5A
ST-2406-10AQ
6/12/24 9A 10A
Open-Frame Transformers
ST-UV16-W50Q
16VAC/50VA
ST-UV16-W100Q
16VAC/100VA
ST-UV24-W50Q
24VAC/50VA
ST-UV24-W100Q
24VAC/100VA
ST-UVDA-W100Q
24/28 VAC/100VA*
ST-UVDA-W180Q
24/28 VAC/180VA*
ST-UV28-T350Q
28VAC/350VA
Dual-input voltage: 120/240 VAC, 50/60 Hz.
Works with the SECO-LARM series of power supplies/
chargers.
Shielded windings to reduce electromagnetic
interference.
*
Dual-voltage output: 24 or 28 VAC
Siren
SH-532L
128dB Multi-tone siren.
Miniature size: 3¼” long, 3½” diameter.
6~12 VDC, 1.4-Amp current draw.
Relay Boards
Easily fit inside alarm panel enclosures
SR-2112-C7AQ/10
12/24 VDC Operation.
7-Amp relay, SPDT, Form C.
12/24 VDC Trigger.
Breakaway 10-pack.
SR-2206-C5AQ
6/12 VDC Operation.
5-Amp Relay, DPDT, Form C.
6/12 VDC Trigger.
Large terminal blocks for
easy installation.
SR-2212-C5AQ
12/24 VDC Operation.
5-Amp relay, DPDT, Form C.
12/24 VDC Trigger.
Large terminal blocks for
easy installation.
SR-1212-C2ALQ
12/24 VDC Operation.
Low current draw: 15mA.
2-Amp relay, DPDT, Form C.
3~24 VDC Trigger.
Large terminal blocks for
easy installation.
SR-1212-C7ALQ
12/24 VDC operation.
High-sensitivity,
low-trigger voltage.
Two 7-Amp relays,
SPDT, Form C.
3~24 VDC Trigger.
sales@associatedtelephone.com Tel | 604.270.0135 Toll Free | 888.270.0135 www.associatedtelephone.com
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23

Comentarios a estos manuales